SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
641
3 Function diagrams
3.10 Safety Integrated Extended Functions
Fig. 3-71 2824 – SDI (Safe Direction)
- 2824 -
Function diagram
87654321
fp_2824_97_58.vsd
Safety Integrated Extended Functions
CU240E-2_F/DP_F
09.12.2015 V4.7.6
SDI (Safe Direction)
SI Mtn int stat P1
r9722
r9722
.12
1 = SDI positive active
SI Mtn integ STW
r9720
r9720
.12
1
0
0
T0
SI Mtn SDI t P1
0.00 ... 600000.00 [ms]
p9565 (100.00)
SI Mtn SDI t P2
0.00 ... 600000000.00 [µs]
p9365 (100000.00)
Monitoring
SI Mtn SDI tol P1
0.001 ... 360.000 [°]
p9564 (12.000)
SI Mtn SDI Stop P1
0 ... 1
p9566 (1)
SI Mtn SDI tol P2
0.001 ... 360.000 [°]
p9364 (12.000)
SI Mtn SDI Stop P2
0 ... 1
p9366 (1)
SI Mtn integ STW
r9720
r9720
.13
1
0
0
r9733[0..2]
SI Mtn setp_lim [rpm]
SI Mtn int stat P1
r9722
r9722
.13
1 = SDI negative active
0 = SDI positive selected
0 = SDI negative selected
Setpoint limitation positive
<1>
<1>
p1082
0
p9531[x] x p9533
0
0
p1082
0
p9531[x] x p9533
|p1082|
|p1082|
|p9531[x] x p9533|
|p9531[x] x p9533|
r9733[0] r9733[1] r9733[2]
Setpoint limitation absoluteSetpoint limitation negative
Selected SI function
Deselection SDI positive
Deselection SDI negative
SDI positive + SLSx
SDI negative + SLSx
1
[2840.5]
[2840.5]
[2840.1]
[2840.1]
1
SI Mtn enable P1
p9501.17
SI Mtn enable P2
p9301.17