SINAMICS G120 Control Units CU240B-2/CU240E-2
List Manual (LH11), 01/2016, A5E33839529
661
3 Function diagrams
3.13 Vector control
Fig. 3-88 6019 – Application classes (p0096), overview
- 6019 -
Function diagram
87654321
fp_6019_97_52.vsd
Vector control
G120 CU240B/E-2
09.12.2015 V4.7.6
Application classes (p0096), overview
Power Module
PM330
(p0300 = 1xx) (p0300 = 2xx) (p0300 = 6xx)
For synchronous motor
p0096 = 0
p0096 = 1
p0096 = 2
p0096 = 0
p0096 = 2
p0096 = 0
p0096 = 2
For reluctance motor
<1>
<1> p0096 = 0: Expert
p0096 = 1: Standard Drive Control (SDC)
p0096 = 2: Dynamic Drive Control (DDC)
p0096 = 0
p0096 = 2
p0096 = 0
p0096 = 2
+ [6799]
Applicable function diagrams:
Possible application classes (p0096)
other
Power Module
Chapter "Vector control, Standard Drive Control (p0096 = 1)"
Chapter "Vector control"
Chapter "Vector control, Dynamic Drive Control (p0096 = 2)"
+ [6490], [6491], [6799]
Chapter "Vector control"
Chapter "Vector control"
Power Module
PM240
PM240-2
PM340
No application class (p0096) possible.
Not available. Not available.
Not available.
Not available. Chapter "Vector control, Dynamic Drive Control (p0096 = 2)"
For induction motor

Table of Contents