Procedure
1. Set the edge of the reference cam signal the converter should use to reference its actual
position value:
0: Rising edge
1: Falling edge
2. Interconnect the switchover of reference cams 1 and 2 with a signal of your choice.
3. Select the digital input with which reference cam 1 is interconnected.
Commissioning
6.6 Referencing
Basic positioner