Procedure
1. Specify the reference point coordinate.
2. Accept the reference point coordinate in the position actual value.
You have now adjusted the absolute encoder.
Parameter Meaning
p2598 Reference point coordinate, signal source
p2599 Reference point coordinate value
p2507 Absolute encoder adjustment status
0 Error has occurred in the adjustment
1 Absolute encoder was not adjusted
2 Absolute encoder was not adjusted and encoder adjustment was initiated
3 Absolute encoder adjusted
Commissioning
6.6 Referencing
Basic positioner
Function Manual, 09/2020, FW V4.7 SP13, A5E34257659B AG 69