Procedure
1. Interconnect the signal that de󹪝nes the mode for the "jog" function.
0: Velocity jogging
1: Incremental jogging
2. Interconnect the signal for jogging 1
3. Interconnect the signal for jogging 2.
4. Select the button for the other settings.
5. Set the velocities for the "jogging 1" function.
6. Set the velocities for the "jogging 2" function.
7. If you use the incremental jog, set the relative position setpoint for the "jogging 1" function.
This value has no signi󹪝cance for velocity jogging.
8. If you use the incremental jog, set the relative position setpoint for the "jogging 2" function.
This value has no signi󹪝cance for velocity jogging.