Procedure
1. Select the button for conguring the xed setpoint:
2. Set the values suitable to your application:
You have set the xed setpoints.
❒
Parameter Meaning
p2640 Intermediate stop (0 signal)
p2641 Reject traversing job (0 signal)
p2642 Direct setpoint input/MDI, position setpoint
p2643 Direct setpoint input/MDI, velocity setpoint
p2644 Direct setpoint input/MDI, acceleration override
p2645 Direct setpoint input/MDI, deceleration override
p2646 Velocity override
p2647 Direct setpoint input/MDI selection
p2648 Direct setpoint input/MDI, positioning type
0 Absolute positioning is selected
1 Relative positioning is selected
p2649 Direct setpoint input/MDI, acceptance method selection
0 Values are accepted when p2650 = 0 → 1
1 Continuous acceptance of values
p2650 Direct setpoint input/MDI, setpoint acceptance, signal edge
p2650 = 0 → 1 and p2649 = 0 signal
p2651 Direct setpoint input/MDI, positive direction selection
p2652 Direct setpoint input/MDI, negative direction selection
p2653 Direct setpoint input/MDI, set up selection
Signal = 1: Set up is selected.
Commissioning
6.9 Direct setpoint input (MDI)
Basic positioner
92 Function Manual, 09/2020, FW V4.7 SP13, A5E34257659B AG