Connecting the motor
-XD0, Han K 4/4, socket Pin Assignment
1 U2
2 V2
3 W2
4 Not assigned
Protective conductor
11 Motor holding brake 180 V DC+
12 Motor holding brake 180 V DC-
13 Temperature sensor +
14 Temperature sensor -
Use a shielded cable for the motor.
For the motor connection, we recommend prefabricated cables made by Harting. The
prefabricated cables have a Han K 4/4 motor plug and a Han K 4/4 plug.
● Length 5 m, cross-section 10 mm
2
Label K4/4 M/F EMC 5G10+2x2x1 5m motor, Article No. 6188202072100
● Length 5 m, cross-section 6 mm
2
Label K4/4 M/F EMC 5G6+2x1+2x1.5 5m motor, Article No. 6188202072200
Other cable lengths are available from Harting.
Connection
4.2 Connecting the line supply and motor
Distributed inverter box
14 Manual, 06/2018, A5E43491109B AB