SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
173
2 Parameters
2.2 List of parameters
Description: Sets the signal source to invert the setpoint.
Dependency: Refer to: r1198
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source to invert the setpoint.
Dependency: Refer to: r1198
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Displays the speed/velocity setpoint after the changeover and limiting the direction.
Description: Sets the ramp-function generator type.
Value: 0: Basic ramp-function generator
1: Extended ramp-function generator
Note: Another ramp-function generator type can only be selected when the motor is at a standstill.
Description: Sets the ramp-function generator type.
Value: 0: Basic ramp-function generator
1: Extended ramp-function generator
p1113[0...n] BI: Setpoint inversion / Setp inv
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: CDS, p0170
Unit group: - Unit selection: - Func. diagram: 2441, 2442, 2505,
3040
Min Max Factory setting
- - [0] 2090.11
[1] 0
[2] 0
[3] 0
p1113[0...n] BI: Setpoint inversion / Setp inv
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: CDS, p0170
Unit group: - Unit selection: - Func. diagram: 2441, 2442, 2505,
3040
Min Max Factory setting
- - 0
r1114 CO: Setpoint after the direction limiting / Setp after limit
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Dyn. index: -
Unit group: 3_1 Unit selection: p0505 Func. diagram: 3001, 3040, 3050
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
p1115 Ramp-function generator selection / RFG selection
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
CU250D-2_PN_F
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3001, 3080
Min Max Factory setting
0 1 0
p1115 Ramp-function generator selection / RFG selection
CU250D-2_DP_F Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 3001, 3080
Min Max Factory setting
0 1 1