2 Parameters
2.2 List of parameters
SINAMICS G120D
226 List Manual (LH14), 01/2016, A5E33842313
Description: Display and connector output for the actual effective upper torque limit.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note: The effective upper torque limit is reduced with respect to the selected upper torque limit p1520, if the current limit
p0640 is reduced or the rated magnetizing current of the induction motor p0320 is increased.
This may be the case for rotating measurements (see p1960).
The torque limit p1520 can be re-calculated using p0340 = 1, 3 or 5.
Description: Display and connector output for the actual effective lower torque limit.
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Note: The effective lower torque limit is reduced with respect to the selected lower torque limit p1521, if the current limit
p0640 is reduced or the rated magnetizing current of the induction motor p0320 is increased.
This may be the case for rotating measurements (see p1960).
The torque limit p1520 can be re-calculated using p0340 = 1, 3 or 5.
Description: Sets the signal source to activate/de-activate the "travel to fixed stop" function
1: Travel to fixed stop is active
0: Travel to fixed stop is inactive
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Description: Sets the signal source to activate/de-activate the "travel to fixed stop" function
1: Travel to fixed stop is active
0: Travel to fixed stop is inactive
Dependency: Not visible with application class: "Standard Drive Control" (SDC, p0096 = 1)
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: When traveling to fixed stop, the fault F07900 "motor blocked" is suppressed.
r1538 CO: Upper effective torque limit / M_max upper eff
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2003 Dyn. index: -
Unit group: 7_1 Unit selection: p0505 Func. diagram: 6020, 6640
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
r1539 CO: Lower effective torque limit / M_max lower eff
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2003 Dyn. index: -
Unit group: 7_1 Unit selection: p0505 Func. diagram: 6020, 6640
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
p1545[0...n] BI: Activates travel to a fixed stop / TfS activation
CU240D-2_DP
CU240D-2_PN
CU240D-2_DP_F
CU240D-2_PN_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: CDS, p0170
Unit group: - Unit selection: - Func. diagram: 2520, 3617, 8012
Min Max Factory setting
- - 0
p1545[0...n] BI: Activates travel to a fixed stop / TfS activation
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: CDS, p0170
Unit group: - Unit selection: - Func. diagram: 2520, 8012
Min Max Factory setting
- - 2683.14