Siemens SINAMICS G120D CU240D-2 DP - p2513[0...3] CI: LR Position actual value preprocessing corrective value; Act val_prep corr; p2514[0...3] BI: LR activate position actual value setting; s_act setting act; p2515[0...3] CI: LR position actual setting setting value; s_act set setVal

Siemens SINAMICS G120D CU240D-2 DP
980 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
335
2 Parameters
2.2 List of parameters
Description: Sets the signal source for the corrective value for position actual value preprocessing.
Index: [0] = Position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency: Refer to: p2502, p2512, r2521, r2685
Note: For BI: p2512[0] = 0/1 signal, the position actual value (CO: r2521[0]) is corrected corresponding to the value via CI:
p2513[0]. In so doing, the sign of the corrective value present is taken into account.
Description: Sets the signal source to activate the function "set position actual value".
Index: [0] = Position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency: Refer to: p2502, p2515
Refer to: A07495, A07497
Warning: As long as the position actual value is set, encoder increments that are received are not evaluated. In this state, any
position difference cannot be corrected!
Notice: When the function "set position actual value" is activated while the function "reference mark search" or "measuring
probe evaluation" is activated, then the corresponding function is de-activated.
Note: BI: p2514 = 1 signal:
The position actual value is set to the setting value in CI: p2515. Alarm A07497 "position setting value activated" is
output. Encoder increments that are received in the meantime, are not taken into account.
BI: p2514 = 1/0 signal:
The position actual value preprocessing is activated and is based on the setting value.
Description: Sets the signal source for the setting value of the function "setting position actual value".
Index: [0] = Position control
[1] = Encoder 1
[2] = Encoder 2
[3] = Reserved
Dependency: Refer to: p2502, p2514
p2513[0...3] CI: LR Position actual value preprocessing corrective value / Act val_prep corr
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Integer32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 4010, 4015
Min Max Factory setting
- - [0] 2685[0]
[1] 0
[2] 0
[3] 0
p2514[0...3] BI: LR activate position actual value setting / s_act setting act
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 4010
Min Max Factory setting
- - 0
p2515[0...3] CI: LR position actual setting setting value / s_act set setVal
CU250D-2_PN_F
CU250D-2_DP_F
Access level: 1 Calculated: - Data type: U32 / Integer32
Can be changed: T Scaling: - Dyn. index: -
Unit group: - Unit selection: - Func. diagram: 4010
Min Max Factory setting
- - 0