SINAMICS G120D
List Manual (LH14), 01/2016, A5E33842313
649
3 Function diagrams
3.6 Internal control/status words
Fig. 3-47 2522 – Status word, speed controller (r1407)
- 2522 -
Function diagram
87654321
fp_2522_97_04.vsd
Internal control/status words
SINAMICS G120D
09.12.2015 V4.7.6
Status word, speed controller (r1407)
1
2
3
...
5
6
7
8
9
10
11
0
12
13
14
15
r1407.8
r1407.9
r1407.17
r1407.1
r1407.7
r1407.10
r1407.11
r1407.5
r1407.6
r1407.2
r1407.3
r1407.12
r1407.13
r1407.0
From the changeover,
closed-loop control types
Status word speed controller (r1407)Bit No.
1 = U/f control active
1 = Sensorless operation active
1 = Closed-loop torque control active
1 = Closed-loop speed control active
1 = Speed controller, I component held
1 = Speed controller, I component set
1 = Torque limit reached
1 = Torque limiting, upper, active
1 = Torque limiting, lower, active
1 = Droop enabled
1 = Speed setpoint limited
1 = Ramp-function generator set
1 = Sensorless operation due to a fault
1 = I/f control active
1 = Torque limit reached (without pre-control)
To speed setpoint, droop [6030.5]
To speed signals 2 [8011.4]
To ramp-function generator tracking [3080.1]
To speed controller [6040.4]
To motor locked/stalled [8012.5]
From the speed setpoint, droop [6030.4], [6030.5]
From the speed setpoint, droop [6030.3]
From the torque setpoint [6060.5], [6060.8]
From the speed controller [6040.7]
From the speed controller [6040.7]
ZSW n_ctrl
r1407
r1407
Reserved
From the torque setpoint [6060.8]
16
17
1 = Encoderless open-loop controlled operation not active
1 = Speed limiting control activeFrom the speed limiting [6640.8]
r1407.14
r1407.15
From the torque setpoint [6060.3]
From the speed controller [6040.7]
From the torque setpoint [6060.5], [6060.8]
From the torque setpoint [6060.3]
r1407.2323
1 = Acceleration model activated
r1407.2424
r1407.2525
r1407.2626
1 = Moment of inertia estimator active
1 = Moment of inertia estimator stabilized
1 = Load estimator active
r1407.16
...
Reserved
r1407.2727
1 = moment of inertia estimator is actively accelerating the motor
From the moment of inertia estimator [6035.4]
From the moment of inertia estimator [6035.4]
From the moment of inertia estimator [6035.4]