EasyManua.ls Logo

Siemens SINAMICS G130 - Page 191

Siemens SINAMICS G130
610 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Operation
6.3 Basic information about the drive system
Inverter chassis units
Operating Instructions, 07/2016, A5E00331449A
191
Properties of a drive object
Separate parameter space
Separate window in STARTER
Separate fault/alarm system
Separate PROFIdrive telegram for process data
Configuring drive objects
When you commission the system for the first time using the STARTER tool, you will use
configuration parameters to set up the software-based "drive objects" which are processed
on the Control Unit. Various drive objects can be created within a Control Unit.
The drive objects are configurable function blocks and are used to execute specific drive
functions.
If you need to configure additional drive objects or delete existing ones after initial
commissioning, the drive system must be switched to configuration mode.
The parameters of a drive object cannot be accessed until the drive object has been
configured and you have switched from configuration mode to parameterization mode.
Note
Assignment during the initial commissioning
Each installed drive object is allocated a number between 0 and 63 during initial
commissioning for unique identification.
Parameters
p0101 Drive object numbers
r0102 Number of drive objects
p0107 Drive object type
p0108 Drive object configuration

Table of Contents

Other manuals for Siemens SINAMICS G130

Related product manuals