Operation
6.6 Communication according to PROFIdrive
Inverter chassis units
238 Operating Instructions, 07/2016, A5E00331449A
Table 6- 19 Parameter response
Response
header
Request reference mirrored = 40 hex
Axis mirrored = 02 hex Number of parameters = 04 hex 2
Notes on the parameter response:
● Request reference mirrored:
This response belongs to the request with request reference 40.
● Request identifier:
02 hex → Write request positive
● Axis mirrored:
02 hex → The value matches the value from the request.
● Number of parameters:
04 hex → The value matches the value from the request.
The drive provides the standard diagnostics for PROFIBUS and PROFINET. This allows the
PROFIdrive classes of the drive to be integrated into the system diagnostics of a higher-level
control system and automatically displayed on an HMI.
The information transferred is saved for the drive objects in the following parameters:
r0947[0...63] fault number
r3120[0..63] component fault
r2122[0...63] alarm code
r3121[0..63] component alarm
r9747[0...63] SI message code
(with safety messages)
r9745[0..63] SI component
(with safety message)
The messages entered in these parameters are combined to create PROFIdrive message
classes for diagnostics. Determining the source of a message is realized by transferring the
component number as channel number.
The diagnostics are activated via the appropriate parameterization in the configuration tool
being used (e.g. via HW Config).
The functional scope of the diagnostic channels depends on the bus system.
PROFIdrive message classes
PROFINET
PROFIBUS