Functions, monitoring, and protective functions
9.3 Extended functions
Inverter chassis units
466 Operating Instructions, 07/2016, A5E00331449A
Table 9- 11 Status message of extended brake control
Command, release brake (continuous
r1229.1 B_STW.1
Pulse enable, extended brake control r1229.3 B_STW.3
Brake does not close r1229.5 B_STW.5
Brake threshold fallen below
Brake monitoring time expired
Request, pulse enable missing/n_ctrl
r1229.9 B_STW.9
Brake OR logic operation result
Brake AND logic operation result
Extended brake control – standstill detection (r0108.14 = 1)
Extended brake control – release/close brake (r0108.14 = 1)
Extended brake control – signal outputs (r0108.14 = 1)
r0108.14
r0899
word sequence control
Standstill (zero-speed) monitoring
r0060
CO: Speed setpoint before the setpoint filter
r0063[0...2]
p1224[0...3]
BI: Apply motor holding brake at standstill
p1225
CI: Standstill detection threshold value
p1226
Standstill monitoring speed threshold
p1227
Standstill detection monitoring time
p1228
Standstill detection delay time
p1276
Motor holding brake standstill detection bypass