List of messages
Display messages
20 05/2020, 4BS0576F-004
Text for event memory entry
2645 !! Fault !! Zero trace faulty Flt>Zero trace as no. 2545, but not retained
3000 !! Inverter fault !! download texts IF>download texts - The transmission of another display language from IMS to the inverter
could not be completed correctly.ATTENTION: most probably all texts in
the display are cancelled.Try again to transmit the new language. If the
message appears again contact our service station.
3001 !! Inverter fault !! Power section U+! IF>Power.Sect.U+ - Fault in converter phase U+ (e.g. power section, triggering, control elec-
tronics) Contact our service station; if necessary, replace the defective
PCBs.
3002 !! Inverter fault !! Power section U-! IF>Power.Sect.U- - Fault in converter phase U+ (e.g. power section, triggering, control elec-
tronics) Contact our service station; if necessary, replace the defective
PCBs.
3003 !! Inverter fault !! Power section V+! IF>Power.Sect.V+ - Fault in converter phase V+ (e.g. power section, triggering, control elec-
tronics) Contact our service station; if necessary, replace the defective
PCBs.
3004 !! Inverter fault !! Power section V-! IF>Power.Sect.V- - Fault in converter phase V+ (e.g. power section, triggering, control elec-
tronics) Contact our service station; if necessary, replace the defective
PCBs.
3005 !! Inverter fault !! Power section W+! IF>Power.Sect.W+ - Fault in converter phase W+ (e.g. power section, triggering, control elec-
tronics) Contact our service station; if necessary, replace the defective
PCBs.
3006 !! Inverter fault !! Power section W-! IF>Power.Sect.W- - Fault in converter phase W+ (e.g. power section, triggering, control elec-
tronics) Contact our service station; if necessary, replace the defective
PCBs.
3007 !! Inverter fault !! Braking transistor IF>BrakeTransist. - Fault at brake transistor (e.g. power section, triggering, control electronics)
Contact our service station; if necessary, replace the defective PCBs.
3008 !! Inverter fault !! Current asymmetry U IF>C-asymmetry U - This fault can occur only at inverters with several converter systems con-
nected in parallel, if the current of one system is so asymmetric in phase U,
that the system becomes overloaded. Check whether the motor supply
lines are set up symmetrically and if all motor connections are put on cor-
rectly and reliably tightened. In case you find no discrepancies please
inform our service station.
3009 !! Inverter fault !! Current asymmetry V IF>C-asymmetry V - This fault can occur only at inverters with several converter systems con-
nected in
parallel, if the current of one system is so asymmetric in phase V,
that the system becomes overloaded. Check whether the motor supply
lines are set up symmetrically and if all motor connections are put on cor-
rectly and reliably tightened. In case you find no discrepancies please
inform our service station.