List of messages
Display messages
40 05/2020, 4BS0576F-004
Msg-
Number
Display line 1
Display line 2
Text for event memory entry
Fault sup-
pression on
Description
3890
P-message 1/T1 =
Line without characters,
Line with -----------------,
Automat.operation,
Autom.disconnect.,
OFF 2,
Set value < 4 mA,
Interlocking,
I-asymm. motor,
Circuit breaker,
no Release,
Fuse,
Fusing mains 1,
Fusing mains 2,
Undervoltage,
Overspeed,
Underspeed,
Motor stalled,
set value lost,
Set value limited,
Setp/actv.dev,
Ball valve open,
Ball valve closed,
Control voltage,
Motor overpress.,
Switch high volt.,
Control transf.,
Ind. mains volt.,
Filter cabinet,
Aux. devices,
EarthCurr.,
!! OFF 2 !!,
Switch interlock,
prog. Text 1, prog. Text 2,
prog. Text 3, prog. Text 4,
prog. Text 5, prog. Text 6,
prog. Text 7, prog. Text 8,
prog. Text 9, prog. Text 10
P-message 1/T2 =
Line without characters,
Line witz-----------------,
Automat.operation,
Autom.disconnect.,
OFF 2,
Set value < 4 mA,
activ,
I-asymm. motor,
Circuit breaker,
missing,
Fuse,
Fusing mains 1,
Fusing mains 2,
Undervoltage,
Overspeed,
Underspeed,
Motor stalled,
set value lost,
Set value limited,
Setp/actv.dev,
Ball valve open,
Ball valve closed,
Control voltage,
Motor overpress.,
Switch high volt.,
Control transf.,
Ind. mains volt.,
Filter cabinet,
Aux. devices,
EarthCurr.,
Operation,
prog. Text 1, prog. Text 2,
prog. Text 3, prog. Text 4,
prog. Text 5, prog. Text 6,
prog. Text 7, prog. Text 8,
prog. Text 9, prog. Text 10
-
This is a user defined operation message.
It is parameterized as per
"P-MESSAGES/P-message 1/T1 = Text selection values" respectively
"P-MESSAGES/P-message 1/T2 = Text selection values".
The text of the message can be taken from a selection of standard texts
(see left-hand column) or may be a programmed text.
Usually it is an operation message, indicating external or clearly defined
statuses of the inverter.
To be able to trace further how the message has been released you have
to recheck parameter "P-MESSAGES/P-message 1/inp."
3891 P-message 2/T1=
as no. 3890
P-message 2/T2=
as no. 3890
- P-message 2: as no. 3890
3892 P-message 3/T1=
as no. 3890
P-message 3/T2=
as no. 3890
- P-message 3: as no. 3890
3893 P-message 4/T1=
as no. 3890
P-message 4/T2=
as no. 3890
- P-message 4: as no. 3890