List of messages
Display messages
05/2020, 4BS0576F-004
41
Msg-
Number
Display line 1
Display line 2
Text for event memory entry
Fault sup-
pression on
Description
3894 P-message 5/T1=
as no. 3890
P-message 5/T2=
as no. 3890
- P-message 5: as no. 3890
3895 P-message 6/T1=
as no. 3890
P-message 6/T2=
as no. 3890
- P-message 6: as no. 3890
3896 P-message 7/T1=
as no. 3890
P-message 7/T2=
as no. 3890
- P-message 7: as no. 3890
3897 P-message 8/T1=
as no. 3890
P-message 8/T2=
as no. 3890
- P-message 8: as no. 3890
3899 T-Off ramp active The parametrized torque ramp after a failure is active. Wait until the drive
stands. If the signal is still available after approx. 10 minutes, please con-
tact our service station.
4041 !! Ctrl.inhib. !! Interruption BUS CLK>Interrpt.BUS As message no. 3451,
at "P-INTERFACES/P-Fieldbus/Rct.BUS=Control inhibit" parameterized
4042 !! Ctrl.inhib. !! BUS Hardware CLK>BUS Hardware As message no. 3452,
at "P-INTERFACES/P-Fieldbus/Rct.BUS=Control inhibit" parameterized
4043 !! Ctrl.inhib. !! Contr. AD missing CLK>contr. AD As message no. 3453,
at "P-INTERFACES/P-Fieldbus/Rct.BUS=Control inhibit" parameterized
4044 !! Ctrl.inhib. !! Interruption RS485 CLK>InterrptRS485 As message no. 3454,
at "P-INTERFACES/P-RS485/Rct.RS485=Control inhibit" parameterized
4045 !! Ctrl.inhib. !! Interr. RS485 (X26) CLK>Int.RS485 X26 As message no. 3455,
at "P-INTERFACES/P-RS485/Rct.RS485=Control inhibit" parameterized
4051 !! Speed OFF !! Interruption BUS SPD>Interrpt.BUS As message no. 3451,
at "P-INTERFACES/P-Fieldbus/Rct.BUS=Speed off" parameterized
4052 !! Speed OFF !! BUS Hardware SPD>BUS Hardware As message no. 3452,
at "P-INTERFACES/P-Fieldbus/Rct.BUS=Speed off" parameterized
4053 !! Speed OFF !! Contr. AD missing SPD>contr. AD As message no. 3453,
at "P-INTERFACES/P-Fieldbus/Rct.BUS=Speed off" parameterized
4054 !! Speed OFF !! Interruption RS485 SPD>InterrptRS485 As message no. 3454,
at "P-INTERFACES/P-RS485/Rct.RS485=Speed off" parameterized
4055 !! Speed OFF !! Interr. RS485 (X26) SPD>Int.RS485 X26 As message no. 3455,
at "P-INTERFACES/P-RS485/Rct.RS485=Speed off" parameterized

Other manuals for Siemens SINAMICS G180