Technical data
C.5 Technical data for operation
Installation and Operating Instructions SINAMICS G180
200 Operating Instructions, 02/2019, 4BS0751-007
C.5
Technical data for operation
Make sure that the following environmental conditions for operation are fulfilled.
The inverters are designed for indoor installation.
Class 3K3 environmental conditions in accordance with EN 60721
Pollution degree 2
Overvoltage category 3
Degree of protection IP20 for compact units
Degree of protection IP21 for cabinet units
Environmental conditions for the inverter application
Climatic conditions
Class 3K3 according to EN 60721-3-3
Atmospheric pressure
860 mbar1060 mbar, corresponds to max. 1000 m above sea level
1)
Ambient temperature
0 °C … + 40 °C
1)
Humidity rating
5 % … 95 %, 1 g/m³25 g/
Mechanical conditions
Class 3M4 acc. to EN 60721-3-3
Vibration load
- Deflection
- Acceleration
0.075 mm at 10 ... 58 Hz
10 m/s² at 58 ... 200 Hz
Shock load
- Acceleration
100 m/s² at 11 ms
Chemical conditions
Class 3C2 according to EN 60721-3-3
Biological conditions
Class 3B1 according to EN 60721-3-3
1)
The units can be operated under different environmental conditions if derating is applied.
For further information, refer to Chapter "Derating" (Page 206).
For further technical data, refer to the technical data sheet.