Technical data
C.5 Technical data for operation
Installation and Operating Instructions SINAMICS G180
200 Operating Instructions, 02/2019, 4BS0751-007
Technical data for operation
Make sure that the following environmental conditions for operation are fulfilled.
The inverters are designed for indoor installation.
● Class 3K3 environmental conditions in accordance with EN 60721
● Pollution degree 2
● Overvoltage category 3
● Degree of protection IP20 for compact units
● Degree of protection IP21 for cabinet units
Environmental conditions for the inverter application
Class 3K3 according to EN 60721-3-3
860 mbar … 1060 mbar, corresponds to max. 1000 m above sea level
1)
1)
5 % … 95 %, 1 g/m³ … 25 g/m³
Class 3M4 acc. to EN 60721-3-3
Vibration load
- Deflection
0.075 mm at 10 ... 58 Hz
Shock load
Class 3C2 according to EN 60721-3-3
Class 3B1 according to EN 60721-3-3
1)
The units can be operated under different environmental conditions if derating is applied.
For further information, refer to Chapter "Derating" (Page 206).
For further technical data, refer to the technical data sheet.