Description
3.3 Accessories
Installation and Operating Instructions SINAMICS G180
56 Operating Instructions, 02/2019, 4BS0751-007
3.3.14
Optional fieldbus connection
3.3.14.1
PROFIBUS DP
You can purchase a PROFIBUS board as accessory. The PROFIBUS board is installed
under the grey plastic cover. The board can be retrofitted. You recognize from the
description "…
Type code
_ _ _ _ P _" on the rating plate that a PROFIBUS board has been
integrated.
More details about the board and the PROFIBUS parameters can be found in the separate
PROFIBUS description.
PROFIBUS connection
Switch for terminating resistor
PROFIBUS address, settable
LED "bus diagnostics"
LED "Offline"
Unused LED
LED "Online"
Figure 3-5 PROFIBUS board
Table 3- 4 PROFIBUS board - external elements
component
Function
LED "Status" (only just
visible under the grey
cover)
Flashing red at different frequencies Hardware fault on the PROFIBUS board: con-
tact Customer Service.
Flashing green at 1 Hz,
0.5 s on, 0.5 s off
PROFIBUS board initialization OK
Flashing green at 2 Hz,
0.25 s on, 0.25 s off
Error when initializing the PROFIBUS board:
contact Customer Service.
LED "Online"
This green LED lights if the bus connection is OK.
LED "Offline"
This red LED lights if the bus connection is interrupted. Check the external bus configuration.