EasyManua.ls Logo

Siemens SINAMICS S 1PH7 - 5.4.10 Connections, Circulating Oil Lubrication, Frame Sizes 132 and 160

Siemens SINAMICS S 1PH7
244 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor components (options)
5.4 Gearbox
1PH7 induction motors (Machine tools)
Configuration Manual, (APH7W), 04/2009, 6SN1197-0AD72-0BP0
205
5.4.10 Connections, circulating oil lubrication, frame sizes 132 and 160
M
K
E
G
L
D
F
O
P
N
H
Figure 5-10 Selector gearbox with selector unit for frame sizes 132 and 160
Table 5- 11 Connections for circulating oil lubrication
Max. pressure Connection
Oil return
Connection
Oil inlet
Mounting position
2 bar H P (1.5 dm
3
/min) V3
0.5 bar
1.5 bar
1.5 bar
M (0.5 dm
3
/min)
N (1.5 dm
3
/min)
V1
(closed version)
1.5 bar
D
Main direction of
rotation
clockwise
1)
E
Main direction of
rotation
counter-clockwise
1)
G (1.5 dm
3
/min)
Main direction of rotation
clockwise
F (1.5 dm
3
/min)
Main direction of rotation
counter-clockwise
B5
V1
Note: Circulating oil lubrication is required for certain gearboxes and V1 or V3 vertical mounting
positions (refer to Chapter "Lubrication")
Connection O is additionally possible (0.5 dm
3
/min)
1)
When viewing the gearbox drive from the motor

Table of Contents

Related product manuals