Assignment, terminal boxes and max. cross-sections
Table 6- 1 Assignment, terminal boxes and max. cross-sections
Shaft
height
Motor type Terminal
box type
Cable
entry
Max.
possible
outer
cable
diameter
2)
Cable entry Max.
possible
outer
cable
diam-
eter
2)
Number of
main
terminals
Max.
connect
able
cross-
section
per
terminal
[mm
2
]
Max.
pos-
sible
current
for
each
ter-
minal
1)
[A]
Valid for the 8th
position of the Order
No. "2", "4", "6"
Valid for the 8th
position of the Order
No. "7", "8"
100 1PH710☐-☐☐☐ integrated PG 29 28 M 32 x 1.5 21 6 x M 5 25 84
132 1PH713☐-☐☐☐ integrated PG 36 34 M 40 x 1.5 28 6 x M 6 35 104
160 1PH716☐-☐☐☐ integrated PG 40 40 M 50 x 1.5 38 6 x M 6 50 123
1PH7184-☐☐☐ 1XB7322 2 x PG 42 40 2 x M 50 x 1.5 38 3 x M 12 2 x 50 191
1PH7186-☐☐D 1XB7322 2 x PG 42 40 2 x M 50 x 1.5 38 3 x M 12 2 x 50 191
1PH7186-☐☐E 1XB7322 2 x PG 42 40 2 x M 50 x 1.5 38 3 x M 12 2 x 50 191
1PH7186-☐☐F 1XB7422 2 x M 72 x 2 56 2 x M 63 x 1.5 53 3 x M 12 2 x 70 242
1PH7186-☐☐L 1XB7422 2 x M 72 x 2 56 2 x M 63 x 1.5 53 3 x M 12 2 x 70 242
180
1PH7186-☐☐T 1XB7322 2 x PG 42 40 2 x M 50 x 1.5 38 3 x M 12 2 x 50 191
1PH7224-☐☐C 1XB7322 2 x PG 42 40 2 x M 50 x 1.5 38 3 x M 12 2 x 50 191
1PH7224-☐☐D 1XB7322 2 x PG 42 40 2 x M 50 x 1.5 38 3 x M 12 2 x 50 191
1PH7224-☐☐F 1XB7322 2 x PG 42 40 2 x M 50 x 1.5 38 3 x M 12 2 x 50 191
1PH7224-☐☐L 1XB7700 3 x M 72 x 2 56 3 x M 75 x 1.5 68 3 x 2 x M 12 3 x 150 583
1PH7226-☐☐D 1XB7422 2 x M 72 x 2 56 2 x M 63 x 1.5 53 3 x M 12 2 x 70 242
1PH7226-☐☐F 1XB7700 3 x M 72 x 2 56 3 x M 75 x 1.5 68 3 x 2 x M 12 3 x 150 583
1PH7226-☐☐L 1XB7700 3 x M 72 x 2 56 3 x M 75 x 1.5 68 3 x 2 x M 12 3 x 150 583
1PH7228-☐☐D 1XB7700 3 x M 72 x 2 56 3 x M 75 x 1.5 68 3 x 2 x M 12 3 x 150 583
1PH7228-☐☐F 1XB7700 3 x M 72 x 2 56 3 x M 75 x 1.5 68 3 x 2 x M 12 3 x 150 583
225
1PH7228-☐☐L 1XB7700 3 x M 72 x 2 56 3 x M 75 x 1.5 68 3 x 2 x M 12 3 x 150 583
1)
Current load capability based on IEC 60204-1, routing type C, Table 5.
2)
Depending on design of the metric cable gland