Connection system
6.6 Signal connection
1PH7 induction motors (Machine tools)
220 Configuration Manual, (APH7W), 04/2009, 6SN1197-0AD72-0BP0
Cables on motors with DRIVE-CLiQ
With DRIVE-CLiQ, the same cable is used for all encoder types. Only pre-assembled cables
from Siemens (MOTION-CONNECT) may be used.
Table 6- 6 Pre-assembled cable
6FX 002 - ☐DC☐☐ - ☐☐☐ 0
5 MOTION-
CONNECTⓇ500
8 MOTION-
CONNECTⓇ800
↓↓↓
Length
max. cable length 100 m
max. cable length 50 m
For other technical data and length code, refer to Catalog, Chapter "MOTION-CONNECT
connection system"
Encoder connection for motors without DRIVE-CLiQ
Motors that are not equipped with DRIVE-CLiQ require a Cabinet-Mounted Sensor Module
when operated with SINAMICS S120. The Sensor Modules evaluate the signals from the
connected motor encoders or external encoders and convert them to DRIVE-CLiQ. In
conjunction with motor encoders, the motor temperature can also be evaluated using Sensor
Modules. For additional information, refer to the SINAMICS Manual.
(
0
a
6,1$0,&66
'5,9(
&/L4
0RWRU
˽
0RWRU
0RGXOH
3RZHUFDEOH
(QFRGHUFRQQHFWLRQYLD6HQVRU0RGXOH&DELQHW
6HQVRU0RGXOH&DELQHW
6LJQDOFDEOH
Figure 6-7 Encoder connection for motors without DRIVE-CLiQ