Connection system
6.6 Signal connection
1PH7 induction motors (Machine tools)
Configuration Manual, (APH7W), 04/2009, 6SN1197-0AD72-0BP0
221
Cables for motors without DRIVE-CLiQ
Only pre-fabricated cables from Siemens (MOTION-CONNECT) may be used.
Table 6- 7 Pre-fabricated cable for incremental encoder
6FX 002 - 2AC31 - ☐☐☐ 0
5 MOTION-
CONNECTⓇ500
8 MOTION-
CONNECTⓇ800
↓↓↓
Length
max. cable length 100 m
max. cable length 50 m
Table 6- 8 Pre-fabricated cable for absolute encoder
6FX 002 - 2EQ10 - ☐☐☐ 0
5 MOTION-
CONNECTⓇ500
8 MOTION-
CONNECTⓇ800
↓↓↓
Length
max. cable length 100 m
max. cable length 50 m
For other technical data and length code, refer to Catalog, Chapter "MOTION-CONNECT
connection system"