List of parameters
Parameters
1-1011
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the delay time for the SLS changeover or for the changeover from SLS to SOS for the function "Safely-Limited
Speed" (SLS).
When transitioning from a higher to a lower safely-limited velocity/speed stage or to the safe operating stop (SOS),
within this delay time, the "old" velocity stage remains active.
Even if SLS or SOS is activated from non safety-related operation, then this delay is still applied.
Note: A change only becomes effective after a POWER ON.
SLS: Safely-Limited Speed / SG: Safely reduced speed
SOS: Safe Operating Stop / SBH: Safe operating stop
Description: Sets the transition time from STOP C to "Safe Operating Stop" (SOS).
Note: A change only becomes effective after a POWER ON.
SOS: Safe Operating Stop / SBH: Safe operating stop
Description: Sets the transition time from STOP D to "Safe Operating Stop" (SOS).
Note: A change only becomes effective after a POWER ON.
SOS: Safe Operating Stop / SBH: Safe operating stop
Description: Sets the transition time from STOP E to "Safe Operating Stop" (SOS).
Note: A change only becomes effective after a POWER ON.
SOS: Safe Operating Stop / SBH: Safe operating stop
p9551 SI motion SLS (SG) changeover delay time (Control Unit) / SI Mtn SLS t CU
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9552 SI motion transition time STOP C to SOS (SBH) (Control Unit) / SI Mtn t C->SOS CU
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9553 SI motion transition time STOP D to SOS (SBH) (Control Unit) / SI Mtn t D->SOS CU
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9554 SI motion transition time STOP E to SOS (SBH) (Control Unit) / SI Mtn time E->SOS
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]