Siemens SINAMICS S Series - p9551 SI motion SLS (SG) changeover delay time (Control Unit); SI Mtn SLS t CU; p9552 SI motion transition time STOP C to SOS (SBH) (Control Unit); SI Mtn t C�>SOS CU; p9553 SI motion transition time STOP D to SOS (SBH) (Control Unit); SI Mtn t D�>SOS CU; p9554 SI motion transition time STOP E to SOS (SBH) (Control Unit); SI Mtn time E�>SOS

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-1011
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the delay time for the SLS changeover or for the changeover from SLS to SOS for the function "Safely-Limited
Speed" (SLS).
When transitioning from a higher to a lower safely-limited velocity/speed stage or to the safe operating stop (SOS),
within this delay time, the "old" velocity stage remains active.
Even if SLS or SOS is activated from non safety-related operation, then this delay is still applied.
Note: A change only becomes effective after a POWER ON.
SLS: Safely-Limited Speed / SG: Safely reduced speed
SOS: Safe Operating Stop / SBH: Safe operating stop
Description: Sets the transition time from STOP C to "Safe Operating Stop" (SOS).
Note: A change only becomes effective after a POWER ON.
SOS: Safe Operating Stop / SBH: Safe operating stop
Description: Sets the transition time from STOP D to "Safe Operating Stop" (SOS).
Note: A change only becomes effective after a POWER ON.
SOS: Safe Operating Stop / SBH: Safe operating stop
Description: Sets the transition time from STOP E to "Safe Operating Stop" (SOS).
Note: A change only becomes effective after a POWER ON.
SOS: Safe Operating Stop / SBH: Safe operating stop
p9551 SI motion SLS (SG) changeover delay time (Control Unit) / SI Mtn SLS t CU
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9552 SI motion transition time STOP C to SOS (SBH) (Control Unit) / SI Mtn t C->SOS CU
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9553 SI motion transition time STOP D to SOS (SBH) (Control Unit) / SI Mtn t D->SOS CU
SERVO, VECTOR Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 2825
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]
p9554 SI motion transition time STOP E to SOS (SBH) (Control Unit) / SI Mtn time E->SOS
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 4
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [ms] 600000.00 [ms] 100.00 [ms]