Parameters
List of parameters
1-102
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the "active" or "inactive" state of a Voltage Sensing Module (VSM).
Values: 0: Component inactive
1: Component active
Dependency: Refer to: p0105, p0145
Description: Displays the "active" or "inactive" state of an encoder interface (Sensor Module).
Values: 0: Component inactive
1: Component active
Dependency: Refer to: p0105, p0145, p0480, p0897
Description: Displays the version of the EPROM data of the Voltage Sensing Module (VSM).
Description: Displays the version of the EPROM data of the Sensor Module.
Dependency: Refer to: r0127, r0157
r0146[0...n] Voltage Sensing Module, active/inactive / VSM act/inact
A_INF, S_INF Can be changed: - Calculated: - Access level: 2
Data type: Integer16 Dynamic index: p0140 Func. diagram: -
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 -
r0146[0...n] Encoder interface active/inactive / Enc_intf act/inact
SERVO, VECTOR Can be changed: - Calculated: - Access level: 2
Data type: Integer16 Dynamic index: EDS, p0140 Func. diagram: -
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 1 -
r0147[0...n] Voltage sensing module, EPROM data version / VSM EEPROM version
A_INF, S_INF Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r0147[0...n] Sensor Module EPROM data version / SM EEPROM version
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: EDS, p0140 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -