Siemens SINAMICS S Series - r9999[0...99] Software error internal supplementary diagnostics; SW_err int diag; p10000 SI sampling time; SI t_sample; p10001 SI delay time for test stop at DO 0... 3; SI t_delay DO; p10002 SI discrepancy monitoring time; SI discrep t_monit

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-1048
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Diagnostics parameter to display additional information for internal software errors.
Only for internal Siemens troubleshooting.
Description: Sets the sampling time for the Terminal Module 54F (TM54F).
Description: Sets the delay time for the test of the digital outputs 0 ... 3 (DO 0 ... 3).
Within this time, for a forced checking procedure of the digital outputs, the signal must have been detected via the
corresponding digital input DI 20 ... 23.
Dependency: Refer to: p10003, p10007, p10041, p10046
Description: Sets the monitoring time for the discrepancy for the digital inputs.
The signal states at the two associated digital inputs (F-DI) must assume the same state within this monitoring time.
Note: F-DI: Failsafe Digital Input
r9999[0...99] Software error internal supplementary diagnostics / SW_err int diag
CU_CX32, CU_S Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p10000 SI sampling time / SI t_sample
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1.00 [ms] 25.00 [ms] 12.00 [ms]
p10001 SI delay time for test stop at DO 0 ... 3 / SI t_delay DO
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
2.00 [ms] 2000.00 [ms] 500.00 [ms]
p10002 SI discrepancy monitoring time / SI discrep t_monit
TM54F_MA,
TM54F_SL
Can be changed: C2 Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 2850, 2851
P-Group: Safety Integrated Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1.00 [ms] 2000.00 [ms] 12.00 [ms]