List of parameters
Parameters
1-107
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the component number for the option board (e.g. terminal board 30).
This unique component number is assigned when parameterizing the topology.
Only component numbers can be entered into this parameter that correspond to an option board.
Description: Sets the number of Command Data Sets (CDS).
Note: It is possible to toggle between command parameters (BICO parameters) using this data set changeover.
Description: Sets the number of Command Data Sets (CDS).
Note: It is possible to toggle between command parameters (BICO parameters) using this data set changeover.
Description: Sets the number of Command Data Sets (CDS).
Note: It is possible to toggle between command parameters (BICO parameters) using this data set changeover.
p0161 Option board, component number / OptBoard comp_no
TB30 Can be changed: C1(4) Calculated: - Access level: 4
Data type: Unsigned8 Dynamic index: - Func. diagram: 9100
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 199 0
p0162 CU-Link slave component number / CX32 comp_no
CU_LINK Can be changed: C1(4) Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Terminals Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 199 0
p0170 Number of Command Data Sets (CDS) / CDS count
A_INF, B_INF,
S_INF, TM41
Can be changed: C1(3) Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1 1 1
p0170 Number of Command Data Sets (CDS) / CDS count
SERVO Can be changed: C1(3) Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1 2 1
p0170 Number of Command Data Sets (CDS) / CDS count
VECTOR Can be changed: C1(3) Calculated: - Access level: 2
Data type: Unsigned8 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
2 4 2