p1151[0...n] Ramp-function generator configuration / RFG config
p1189[0...n] Speed setpoint configuration / n_ctrl config
p1189[0...n] Velocity setpoint configuration / v_ctrl config
p1192[0...n] DSC enc selection / DSC enc selection
p1193[0...n] DSC encoder adaptation factor / DSC encodAdaptFact
p1200[0...n] FlyRest oper mode / FlyRest op_mode
p1202[0...n] FlyRest srch curr / FlyRest srch curr
p1203[0...n] Flying restart search rate factor / FlyRst v_Srch Fact
p1240[0...n] Vdc controller or Vdc monitoring configuration / Vdc_ctrl config
p1243[0...n] Vdc_max controller dynamic factor / Vdc_max dyn_factor
p1244[0...n] DC link voltage threshold upper / Vdc upper thresh
p1245[0...n] Vdc_min controller switch-in level (kinetic buffering) / Vdc_min on_level
p1247[0...n] Vdc_min controller dynamic factor (kinetic buffering) / Vdc_min dyn_factor
p1248[0...n] DC link voltage threshold lower / Vdc lower thresh
p1249[0...n] Vdc_max controller speed threshold / Vdc_max n_thresh
p1250[0...n] Vdc controller proportional gain / Vdc_ctrl Kp
p1251[0...n] Vdc controller integral time / Vdc_ctrl Tn
p1252[0...n] Vdc controller rate time / Vdc_ctrl t_rate
p1255[0...n] Vdc_min controller time threshold / Vdc_min t_thresh
p1256[0...n] Vdc_min controller response (kinetic buffering) / Vdc_min response
p1257[0...n] Vdc_min controller speed threshold / Vdc_min n_thresh
p1262[0...n] Bypass dead time / Bypass t_dead
p1280[0...n] Vdc controller or Vdc monitoring configuration (V/f) / Vdc_ctr config V/f
p1283[0...n] Vdc_max controller dynamic factor (V/f) / Vdc_max dyn_factor
p1285[0...n] Vdc_min controller switch-in level (kinetic buffering) (V/f) / Vdc_min on_level
p1287[0...n] Vdc_min controller dynamic factor (kinetic buffering) (V/f) / Vdc_min dyn_factor
p1289[0...n] Vdc_max controller speed threshold (V/f) / Vdc_max n_thresh
p1290[0...n] Vdc controller proportional gain (V/f) / Vdc_ctrl Kp
p1291[0...n] Vdc controller integral time (V/f) / Vdc_ctrl Tn
p1292[0...n] Vdc controller rate time (V/f) / Vdc_ctrl t_rate
p1293[0...n] Vdc controller output limit (V/f) / Vdc_ctrl outp_lim
p1295[0...n] Vdc_min controller time threshold (V/f) / Vdc_min t_thresh
p1296[0...n] Vdc_min controller response (kinetic buffering) (V/f / Vdc_min response
p1297[0...n] Vdc_min controller speed threshold (V/f) / Vdc_min n_thresh
p1300[0...n] Open-loop/closed-loop control operating mode / Op/cl-lp ctrl_mode
p1310[0...n] Voltage boost permanent / V_boost perm
p1311[0...n] Voltage boost at acceleration / V_boost accelerate
p1317[0...n] V/f control diagnostics activation / Uf diagn act
p1318[0...n] V/f control ramp-up/ramp-down time / Uf t_rmp-up_rmp-dn
p1319[0...n] V/f control voltage at zero frequency / Uf V at f=0 Hz
p1320[0...n] V/f control programmable characteristic frequency 1 / Uf char f1
p1321[0...n] V/f control programmable characteristic voltage 1 / Uf char U1
p1322[0...n] V/f control programmable characteristic frequency 2 / Uf char f2
p1323[0...n] V/f control programmable characteristic voltage 2 / Uf char U2
p1324[0...n] V/f control programmable characteristic frequency 3 / Uf char f3
p1325[0...n] V/f control programmable characteristic voltage 3 / Uf char U3
p1326[0...n] V/f control programmable characteristic frequency 4 / Uf char f4
p1327[0...n] V/f control programmable characteristic voltage 4 / Uf char U4
p1335[0...n] Slip compensation, scaling / Slip comp scal
p1336[0...n] Slip compensation limit value / Slip comp lim val
p1338[0...n] V/f mode resonance damping gain / Uf Res_damp gain
p1339[0...n] V/f mode resonance damping filter time constant / Uf Res_damp T
p1340[0...n] I_max frequency controller proportional gain / I_max_ctrl Kp