Parameters for data sets
Parameters
1-1087
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
p1982[0...n] Pole position identification selection / PolID selection
p1991[0...n] Motor changeover, angular commutation correction / Ang_com corr
p1993[0...n] Pole position identification current, motion-based / PolID I mot_bas
p1994[0...n] Pole position identification rise time motion-based / PolID T mot_bas
p1995[0...n] Pole position identification gain, motion-based / PolID kp mot_bas
p1996[0...n] Pole position identification, integral time motion-based / PolID Tn mot_bas
p1997[0...n] Pole position identification, smoothing time motion-based / PolID t_sm mot_bas
p1999[0...n] Ang. commutation offset calibr. and pole position ID - scaling / ComOffsCalib scal
p3050[0...n] Motor identification - stator resistance / MotId R_stator
p3054[0...n] Motor identification - rotor resistance / MotId R_rotor
p3056[0...n] Motor identification - stator leakage inductance / MotId L_stat leak
p3058[0...n] Motor identification - rotor leakage inductance / MotId L_rot leak
p3060[0...n] Motor identification - magnetizing inductance / MotId Lh
1.3.5 Parameters for Power unit Data Sets (PDS)
The following list contains the parameters that are dependent on the Power unit Data Sets.
Product: SINAMICS S, Version: 2503100, Language: eng
p0121[0...n] Power unit component number / PU comp_no
p0124[0...n] Power unit detection via LED / PU detection LED
p0125[0...n] Activate/de-activate power unit components / PU_comp act/de-act
r0126[0...n] Power unit components active/inactive / PU comp act/inact
r0127[0...n] Power unit version EPROM data / PU EPROM version
r0128[0...n] Power unit, firmware version / PU FW version
r0200[0...n] Power unit, actual code number / PU code no. actual
p0201[0...n] Power unit code number / PU code number
r0203[0...n] Actual power unit type / PU actual type
r0204[0...n] Power unit hardware properties / PU HW property
p0251[0...n] Operating hours counter power unit fan / PU fan t_oper
p0895[0...n] BI: Activate/de-activate power unit components / PU_comp act/de-act
p3469[0...n] Latch delay time correction, zero crossover detection / t_latch corr PLL
p3902[0...n] Power unit EEPROM Vdc calibration / PU EEPROM Vdc_cal
p7001[0...n] Par_circuit enable power units / Enable PU
r7002[0...n] Par_circuit status power units / Status PU
r7020[0...n] CO: Par_circuit deviation current in phase U / Phase U curr dev
r7021[0...n] CO: Par_circuit deviation current in phase V / Phase V curr dev
r7022[0...n] CO: Par_circuit deviation current in phase W / Phase W curr dev
r7030[0...n] CO: Par_circuit DC link voltage deviation / Vdc deviation
p7040[0...n] Par_circuit correction valve lockout time phase U / Comp t_lockout U
p7042[0...n] Par_circuit correction valve lockout time phase V / Comp t_lockout V
p7044[0...n] Par_circuit correction valve lockout time phase W / Comp t_lockout W
r7050[0...n] Par_circuit circulating current phase U / Circ_I_phase U
r7051[0...n] Par_circuit circulating current phase V / Circ_I_phase V
r7052[0...n] Par_circuit circulating current phase W / Circ_I_phase W
r7200[0...n] Par_circuit power unit overload I2T / PU overload I2T
Note:
References: /FH1/ SINAMICS S120 Function Manual Drive Functions
Section "Data sets"

Table of Contents