List of parameters
Parameters
1-109
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Using the parameter, each Drive Data Set (= index) is assigned the associated Encoder Data Set (EDS) for
encoder 3.
The parameter value therefore corresponds to the number of the assigned encoder data set.
Note: A value of 99 means that no encoder has been assigned to this drive data set (not configured).
Description: Displays the properties supported by the power unit firmware.
Notice: This information represents the characteristics/features of the power unit firmware. It does not provide informa-
tion/data about the characteristics/features of the hardware (e.g. bit 06 = 1 means that although the firmware sup-
ports "liquid cooling", a power unit with liquid cooling does not have to be used).
Note: Re bit 09:
The Motor Module supports the internal armature short-circuit. The function is internally required for voltage protec-
tion (p1231 = 3).
Re bit 10:
The Motor Module supports the autonomous internal voltage protection. If the voltage protection function is inter-
nally activated (p1231 = 3) the Motor Module decides autonomously - using the DC link voltage - as to whether the
short-circuit is activated.
p0189[0...n] Encoder 3 encoder data set number / Enc 3 EDS number
SERVO, VECTOR Can be changed: C1(4) Calculated: - Access level: 3
Data type: Unsigned8 Dynamic index: DDS, p0180 Func. diagram: 1580, 8570
P-Group: Data sets Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 99 99
r0192 Power unit firmware properties / PU FW property
A_INF, B_INF,
SERVO, S_INF,
VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Converter Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Edge modulation possible Yes No -
01 Free telegram can be selected Yes No -
02 Smart mode possible for Active Line Module Yes No -
03 Safety Integrated possible for VECTOR Yes No -
06 Liquid cooling Yes No -
07 SERVO pulse frequency changeover, DDS-
dependent
Yes No -
08 Simulation operation possible Yes No -
09 Internal armature short-circuit possible Yes No -
10 Autonomous internal armature short-circuit
possible
Yes No -
11 Infeed temperature inputs X21:1, X21:2 Yes No -
12 Integral normalized to half the gating unit
clock cycle freq.
Yes No -
13 Preparation thermal drive converter current
limit
Yes No -