Function Diagrams
Setpoint channel not activated
2-1236
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-122 3095 – Generating the speed limits (r0108.8 = 0)
- 3095 -
Function diagram
87654321
fp_3095_01_eng.vsd
DO: SERVO
SINAMICS S
22.05.07 V02.05.00
Setpoint channel not activated - Generating the speed limits (r0108.8 = 0)
[3020.6]
[3060.4]
[3070.4]
[5300.1]
<1> With OFF1/OFF3, the deceleration ramp of the basic ramp-function generator is active (p1135 or p1121).
<100> Applies only if the function module "expanded setpoint channel" (r0108.8 = 0) is not active. For r0108.8 = 1, [3050] applies instead of [3095].
n_limit neg
-210 000.000...0.000 RPM
p1086[D] (-210 000.000)
Reference value for the ramp-function generator
Max
-1
Min
<1>
<100>
n_limit pos effective
r1084
[5030.5]
[5210.1]
[8010.2]
n_limit neg effective
r1087
[5030.5]
[5210.1]
[8010.2]
n_limit pos
0.000...210 000.000 RPM
p1083[D] (210 000.000)
Maximum speed
0.000...210 000.000 RPM
p1082[D] (1500.000)
Speed limits if a setpoint channel
has not been activated
(r0108.8 = 0).
0
0
p1083[D]
n_limit pos
p1086[D]
n_limit neg
p0115[3] (4000.00 µs)