EasyManua.ls Logo

Siemens SINAMICS S Series - Figure 2-158 5490 - Speed control configuration

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function Diagrams
Servo control
2-1276
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Figure 2-158 5490 – Speed control configuration
- 5490 -
Function diagram
87654321
fp_5490_01_eng.vsd
DO: SERVO
SINAMICS S
14.05.07 V02.05.00
Servo control - Speed control configuration
1
2
3
4
5
6
Reserved
Meaning
Reserved
Reserved
Reserved
1 = Torque limiting active in motoring/regenerating mode
0
Bit No.
Speed control configuration
1
[5020.3]
[5640.3]
[5040.2]
[5210.5]
p1400[D]
p1400[D]
n_ctrl config
Factory setting
1000.00 µs
1 = Kp/Tn adaptation active
Reserved
7
8
10
11
12
1 = Interpolation, speed pre-control active
1 = Interpolation, torque setpoint active
Speed pre-control
0 = To setpoint filter 2; 1 = To balancing
Sensorless operation, speed actual value starting value
0 = 0.0; 1 = setpoint
1
1
[5210.2]
[5020.5]
[5610.6]
Sensorless operation, changeover
0 = When accelerating, 1 = Stationary
13
14
Motoring/regenerating mode depending on:
0 = Speed actual value, 1 = Speed setpoint
Reserved
Reserved15
9 1 = Damping for sensorless open-loop controlled mode
1