EasyManua.ls Logo

Siemens SINAMICS S Series - p0595 Selecting technological units; Select tech units; p0596 Reference quantity, technological units; Ref tech units

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-207
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Selects the units for the parameters of the technology controller.
Values: 1: %
2: 1 referred, no dimensions
3: Bar
4: °C
5: Pa
6: ltr/s
7: m³/s
8: ltr/min
9: m³/min
10: ltr/h
11: m³/h
12: kg/s
13: kg/min
14: kg/h
15: t/min
16: t/h
17: N
18: kN
19: Nm
20: psi
21: °F
22: gallon/s
23: inch³/s
24: gallon/min
25: inch³/min
26: gallon/h
27: inch³/h
28: lb/s
29: lb/min
30: lb/h
31: lbf
32: lbf ft
Dependency: Only units of parameters with unit group 9_1 can be changed over using this parameter.
Refer to: p0596
Description: Sets the reference quantity for the technological units. When changing-over using changeover parameter 595 to
absolute units, all of the parameters involved refer to the reference quantity.
Dependency: Refer to: p0595
p0595 Selecting technological units / Select tech units
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed: C2(5) Calculated: - Access level: 1
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Applications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
1 32 1
p0596 Reference quantity, technological units / Ref tech units
SERVO (Tech_ctrl),
VECTOR (Tech_ctrl)
Can be changed: T Calculated: - Access level: 1
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0.01 340.28235E36 1.00

Table of Contents

Related product manuals