Siemens SINAMICS S Series - p0601 Temperature sensor, sensor type; Temp_sens type; p0601[0...n] Motor temperature sensor type; Mot temp_sensortyp

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-209
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the sensor type for the temperature measurement at input X21 (booksize) or X41 (chassis).
The measured value is displayed in r0035.
Values: 0: No sensor available
1: PTC thermistor
2: KTY84
4: Bemetallic switch
Dependency: Refer to: r0035
Note: The measured value display depends on the selected sensor type.
Re p0601 = 1 (PTC):
Tripping resistance = 1650 Ohm (lower resistance --> r0035 = -50 °C, higher resistance --> r0035 = 250 °C).
Re p0601 = 2 (KTY84):
Displays the temperature in °C.
Re p0601 = 4 (bimetallic switch):
Tripping resistance = 100 Ohm (lower resistance --> r0035 = -50 °C, higher resistance --> r0035 = 250 °C).
When using the following components, a value of 4 is set as the factory setting and can no longer be changed:
- Basic Line Module (BLM) with internal Braking Module.
- Active Line Module (ALM) with line filter Active Interface Module (AIM, p0220[0] = 41 ... 45).
In these cases, in addition to the temperature display, the temperature is also monitored.
Description: Sets the sensor type for the motor temperature monitoring.
Values: 0: No sensor available
1: PTC thermistor
2: KTY84
3: KTY84 and PTC (only for temperature sensor via encoder)
4: Bemetallic switch
10: Evaluation via several temperature channels
Dependency: Refer to: r0458, p0600
Note: PTC thermistor (p0601 = 1): Tripping resistance = 1650 Ohm.
The temperature sensor for the temperature evaluation is set in p0600.
For p0600 = 10 (temperature sensor via a BICO interconnection), the setting in p0601 has no significance.
Re p0601 = 10:
When evaluating using SME120 or SME125 (r0458.8 = 1), 4 temperature channels are available ( parameterized
using p4600, p4601, p4602, p4603).
When evaluating using CU310 and CUA32, 2 temperature channels are available (encoder interface, parameteriza-
tion via p4600 / terminal strip, parameterization via p4601).
p0601 Temperature sensor, sensor type / Temp_sens type
A_INF, B_INF,
S_INF
Can be changed: C2(3), U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 4 0
p0601[0...n] Motor temperature sensor type / Mot temp_sensortyp
SERVO, VECTOR Can be changed: C2(3), U, T Calculated: - Access level: 2
Data type: Integer16 Dynamic index: MDS, p0130 Func. diagram: 8016
P-Group: Motor Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 10 2

Table of Contents