Siemens SINAMICS S Series - p0652[0...n] Motor stator resistance, scaling; Mot R_stator scal; p0653[0...n] Motor stator leakage inductance, scaling; Mot L_S_leak scal; p0655[0...n] Motor magnetizing inductance, d axis saturated scaling; Mot L_m d sat scal; p0656[0...n] Motor magnetizing inductance, q axis, saturated scaling; Mot L_m q sat scal

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-220
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Factor to evaluate the stator resistance.
Dependency: Refer to: p0350, r0370
Description: Factor to evaluate the stator leakage inductance.
Dependency: Refer to: p0356, r0377
Description: Factor to evaluate the magnetizing inductance in the direction of the rotor axis (d axis).
Dependency: Refer to: p0360, r0382
Description: Factor to evaluate the magnetizing inductance quadrature to the rotor axis (q axis).
Dependency: Refer to: p0361, r0383
Description: Factor to evaluate the damping inductance in the direction of the rotor axis (d axis).
Dependency: Refer to: p0358, r0380
p0652[0...n] Motor stator resistance, scaling / Mot R_stator scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0653[0...n] Motor stator leakage inductance, scaling / Mot L_S_leak scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0655[0...n] Motor magnetizing inductance, d axis saturated scaling / Mot L_m d sat scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0656[0...n] Motor magnetizing inductance, q axis, saturated scaling / Mot L_m q sat scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0657[0...n] Motor damping inductance, d axis scaling / Mot L_damp d scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]

Table of Contents

Related product manuals