Parameters
List of parameters
1-220
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Factor to evaluate the stator resistance.
Dependency: Refer to: p0350, r0370
Description: Factor to evaluate the stator leakage inductance.
Dependency: Refer to: p0356, r0377
Description: Factor to evaluate the magnetizing inductance in the direction of the rotor axis (d axis).
Dependency: Refer to: p0360, r0382
Description: Factor to evaluate the magnetizing inductance quadrature to the rotor axis (q axis).
Dependency: Refer to: p0361, r0383
Description: Factor to evaluate the damping inductance in the direction of the rotor axis (d axis).
Dependency: Refer to: p0358, r0380
p0652[0...n] Motor stator resistance, scaling / Mot R_stator scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0653[0...n] Motor stator leakage inductance, scaling / Mot L_S_leak scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0655[0...n] Motor magnetizing inductance, d axis saturated scaling / Mot L_m d sat scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0656[0...n] Motor magnetizing inductance, q axis, saturated scaling / Mot L_m q sat scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0657[0...n] Motor damping inductance, d axis scaling / Mot L_damp d scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]