List of parameters
Parameters
1-221
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Factor to evaluate the damping inductance quadrature to the rotor axis (q axis).
Dependency: Refer to: p0359, r0381
Description: Factor to evaluate the damping resistance in the direction of the rotor axis (d axis).
Dependency: Refer to: p0354, r0374
Description: Factor to evaluate the damping resistance quadrature to the rotor axis (q axis).
Dependency: Refer to: p0355, r0375
Description: Sets the digital input used for the function "central measuring probe evaluation".
p0680[0]: Digital input, measuring probe 1
p0680[1]: Digital input, measuring probe 2
p0680[2]: Digital input, measuring probe 3
p0680[3]: Digital input, measuring probe 4
p0680[4]: Digital input, measuring probe 5
p0680[5]: Digital input, measuring probe 6
Values: 0: No meas probe
1: DI/DO 9 (X122.8/X121.8)
2: DI/DO 10 (X122.10/X121.10)
3: DI/DO 11 (X122.11/X121.11)
4: DI/DO 13 (X132.8)
5: DI/DO 14 (X132.10)
6: DI/DO 15 (X132.11)
p0658[0...n] Motor damping inductance, q axis scaling / Mot L_damp q scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0659[0...n] Motor damping resistance, d axis scaling / Mot R_damp d scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0660[0...n] Motor damping resistance, q axis scaling / Mot R_damp q scal
VECTOR Can be changed: C2(3), U, T Calculated: CALC_MOD_EQU Access level: 4
Data type: Floating Point Dynamic index: MDS, p0130 Func. diagram: -
P-Group: Motor Units group: - Unit selection: -
Not for motor type: ASM, PEM, REL Expert list: 1
Min Max Factory setting
10.0 [%] 300.0 [%] 100.0 [%]
p0680[0...5] Central measuring probe, input terminal / Cen meas inp
CU_CX32, CU_S Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dynamic index: - Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 6 0