Parameters
List of parameters
1-232
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Notice: To the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note: Inversion using p0748 has been taken into account.
The setting of the DI/DO as either input or output is of no significance (p0728).
DI/DO: Bidirectional Digital Input/Output
Description: Displays the status of digital outputs.
Description: Setting to invert the signals at the digital outputs.
Notice: To the terminal designation:
The first designation is valid for CU320, the second for CU310.
Note: DI/DO: Bidirectional Digital Input/Output
Description: Setting to invert the signals at the digital outputs.
13 DI/DO 13 (X132.8) High Low -
14 DI/DO 14 (X132.10) High Low -
15 DI/DO 15 (X132.11) High Low -
r0747 CX digital outputs, status / CX DO status
CU_CX32 Can be changed: - Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: -
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
08 DI/DO 8 (X122.7) High Low -
09 DI/DO 9 (X122.8) High Low -
10 DI/DO 10 (X122.10) High Low -
11 DI/DO 11 (X122.11) High Low -
p0748 CU, invert digital outputs / CU DO invert
CU_S Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 2030, 2031,
2130, 2131, 2132, 2133
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
08 DI/DO 8 (X122.7/X121.7) Inverted Not inverted -
09 DI/DO 9 (X122.8/X121.8) Inverted Not inverted -
10 DI/DO 10 (X122.10/X121.10) Inverted Not inverted -
11 DI/DO 11 (X122.11/X121.11) Inverted Not inverted -
12 DI/DO 12 (X132.7) Inverted Not inverted -
13 DI/DO 13 (X132.8) Inverted Not inverted -
14 DI/DO 14 (X132.10) Inverted Not inverted -
15 DI/DO 15 (X132.11) Inverted Not inverted -
p0748 CX invert digital outputs / CX DO invert
CU_CX32 Can be changed: U, T Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: - Func. diagram: 2230, 2231
P-Group: Commands Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin