Description: Is used to assign the process data received from the master (PZD, setpoints).
Values: 0: ZERO
4201: r4201 (system time for synchronization)
4204: r4204 (control digital output 0 ... 15)
4205: r4205 (control digital output 16 ... 23)
4211: r4211 (edge mode digital input 0 ... 7)
4212: r4212 (edge mode digital input 8 ... 15)
4213: r4213 (edge mode digital input 16 ... 23)
4250: r4250 (set/resetting time digital output 0)
4251: r4251 (set/resetting time digital output 1)
4252: r4252 (set/resetting time digital output 2)
4253: r4253 (set/resetting time digital output 3)
4254: r4254 (set/resetting time digital output 4)
4255: r4255 (set/resetting time digital output 5)
4256: r4256 (set/resetting time digital output 6)
4257: r4257 (set/resetting time digital output 7)
4258: r4258 (set/resetting time digital output 8)
4259: r4259 (set/resetting time digital output 9)
p0915[0...29] TM15 PROFIdrive PZD setpoint assignment / TM15 PD PZD setp
TM15 Can be changed: T Calculated: - Access level: 2
Data type: Unsigned16 Dynamic index: - Func. diagram: -
P-Group: Communications Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
0 4273 [0] 4201
[1] 4204
[2] 4205
[3] 4211
[4] 4212
[5] 4213
[6] 0
[7] 0
[8] 0
[9] 0
[10] 0
[11] 0
[12] 0
[13] 0
[14] 0
[15] 0
[16] 0
[17] 0
[18] 0
[19] 0
[20] 0
[21] 0
[22] 0
[23] 0
[24] 0
[25] 0
[26] 0
[27] 0
[28] 0
[29] 0