Description: Sets the signal source for the speed limit of the positive direction.
Description: Sets the signal source for the velocity limit of the positive direction.
Description: Sets the speed limit for the negative direction.
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description: Sets the velocity limit for the negative direction.
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description: Displays the effective negative speed limit.
Dependency: Refer to: p1082, p1086, p1088
p1085[0...n] CI: Speed limit in positive direction of rotation / n_limit pos
SERVO (Extended
setp), VECTOR
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 3050
P-Group: Setpoints Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 1083[0]
p1085[0...n] CI: Velocity limit positive direction / v_limit pos
SERVO (Extended
setp, Lin)
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dynamic index: CDS, p0170 Func. diagram: 3050
P-Group: Setpoints Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 1083[0]
p1086[0...n] CO: Speed limit negative direction of rotation / n_limit neg
SERVO, VECTOR Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 3050
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
-210000.000 [RPM] 0.000 [RPM] -210000.000 [RPM]
p1086[0...n] CO: Velocity limit negative direction / v_limit neg
SERVO (Lin) Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 3050
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
-1000.000 [m/min] 0.000 [m/min] -1000.000 [m/min]
r1087 Speed limit negative effective / n_limit neg eff
SERVO, VECTOR Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3050, 5030,
5210, 6640, 7020, 8010
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]