Parameters
List of parameters
1-326
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the tolerance value for the status of the ramp-function generator (ramp-up active, ramp-down active).
If the input of the ramp-function generator does not change in comparison to the output by more than the entered
tolerance time, then the status bits "ramp-up active" and "ramp-down active" are not influenced.
Dependency: Refer to: r1199
Description: Displays the acceleration of the ramp-function generator.
Description: Displays the acceleration of the ramp-function generator.
Description: Displays the setpoint at the output of the ramp-function generator.
Description: Displays the setpoint at the output of the ramp-function generator.
p1148[0...n] Ramp-function gen., tolerance for ramp-up and ramp-down active / RFG tol HL/RL act
SERVO (Extended
setp, Lin)
Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 3060, 3070
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [m/min] 10.00 [m/min] 0.20 [m/min]
r1149 CO: Ramp-function generator, acceleration / RFG acceleration
SERVO (Extended
setp), VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3060, 3070
P-Group: Setpoints Units group: 39_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [1/s²] - [1/s²] - [1/s²]
r1149 CO: Ramp-function generator, acceleration / RFG acceleration
SERVO (Extended
setp, Lin)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3060, 3070
P-Group: Setpoints Units group: 22_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/s²] - [m/s²] - [m/s²]
r1150 CO: Ramp-function generator speed setpoint at the output / RFG n_set at outp
SERVO (Extended
setp), VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1550, 3060,
3070, 3080
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r1150 CO: Ramp-function generator velocity setpoint at the output / RFG n_set at outp
SERVO (Extended
setp, Lin)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1550, 3060,
3070, 3080
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]