Siemens SINAMICS S Series - p1148[0...n] Ramp-function gen., tolerance for ramp-up and ramp-down active; RFG tol HL;RL act; r1149 CO: Ramp-function generator, acceleration; RFG acceleration; r1150 CO: Ramp-function generator speed setpoint at the output; RFG n_set at outp; r1150 CO: Ramp-function generator velocity setpoint at the output; RFG n_set at outp

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-326
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the tolerance value for the status of the ramp-function generator (ramp-up active, ramp-down active).
If the input of the ramp-function generator does not change in comparison to the output by more than the entered
tolerance time, then the status bits "ramp-up active" and "ramp-down active" are not influenced.
Dependency: Refer to: r1199
Description: Displays the acceleration of the ramp-function generator.
Description: Displays the acceleration of the ramp-function generator.
Description: Displays the setpoint at the output of the ramp-function generator.
Description: Displays the setpoint at the output of the ramp-function generator.
p1148[0...n] Ramp-function gen., tolerance for ramp-up and ramp-down active / RFG tol HL/RL act
SERVO (Extended
setp, Lin)
Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 3060, 3070
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [m/min] 10.00 [m/min] 0.20 [m/min]
r1149 CO: Ramp-function generator, acceleration / RFG acceleration
SERVO (Extended
setp), VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3060, 3070
P-Group: Setpoints Units group: 39_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [1/s²] - [1/s²] - [1/s²]
r1149 CO: Ramp-function generator, acceleration / RFG acceleration
SERVO (Extended
setp, Lin)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 3060, 3070
P-Group: Setpoints Units group: 22_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/s²] - [m/s²] - [m/s²]
r1150 CO: Ramp-function generator speed setpoint at the output / RFG n_set at outp
SERVO (Extended
setp), VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1550, 3060,
3070, 3080
P-Group: Setpoints Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [RPM] - [RPM] - [RPM]
r1150 CO: Ramp-function generator velocity setpoint at the output / RFG n_set at outp
SERVO (Extended
setp, Lin)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 1550, 3060,
3070, 3080
P-Group: Setpoints Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [m/min] - [m/min] - [m/min]