Siemens SINAMICS S Series - r1407.0...14 CO;BO: Status word speed controller; ZSW n_ctrl; r1408.0...9 CO;BO: Status word closed-loop current control; ZSW curr ctrl

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-385
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
- it is not permissible that OFF1, OFF3 or STOP2 are active.
- it is not permissible that the motor data identification is active.
- it is not permissible that the master control is active.
The following conditions can mean that the DSC function is not active in spite of the fact that the bit is set:
- clock-cycle synchronous operation is not selected (r2054 not equal to 4).
- the PROFIBUS is not clock-cycle synchronous (r2064[0] not equal to 1).
- DSC is not switched-in on the control side; this means that KPC = 0 is transferred as value at CI: p1191.
Description: Displays the status word of the speed controller.
Description: Displays the status word of the closed-loop current control.
Note: The selected current limit is taken into account by the upstream torque limiting; this is the reason that bits 6, 7 and
8 are only set for overshoots due to the current setpoint filter.
r1407.0...14 CO/BO: Status word speed controller / ZSW n_ctrl
VECTOR (n/M) Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 1530, 2522
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 V/f control active Yes No -
01 Sensorless operation active Yes No -
02 Torque control active Yes No 6030
03 Speed control active Yes No 6040
05 Speed controller I component frozen Yes No 6040
06 Speed controller I component set Yes No 6040
07 Torque limit reached Yes No 6060
08 Upper torque limit active Yes No -
09 Lower torque limit active Yes No -
10 Droop enabled Yes No 6030
11 Speed setpoint limited Yes No 6030
12 Ramp-function generator set Yes No -
13 Sensorless operation due to a fault Yes No -
14 I/f control active Yes No -
r1408.0...9 CO/BO: Status word closed-loop current control / ZSW curr ctrl
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 2530, 5040
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Cl-loop curr ctrl Active Not active -
04 Limit Vd Active Not active -
05 Limit Vq Active Not active -
06 Positive limiting Iq Active Not active -
07 Negative limiting Iq Active Not active -
08 Limit iq_set Active Not active -
09 Limit id_set Active Not active -