Siemens SINAMICS S Series - r1408.0...12 CO;BO: Status word closed-loop current control; ZSW curr ctrl; p1412[0...n] Speed setpoint filter, dead time; n_set dead time; p1414[0...n] Speed setpoint filter activation; n_set_filt active; p1414[0...n] Velocity setpoint filter activation; v_set_filt active

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-386
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Displays the status word of the closed-loop current control.
Description: Sets the delay of the speed setpoint for the incremental encoder emulation.
Description: Activates the speed setpoint filters 1 and 2.
Recommend.: If only one filter is required, filter 1 should be activated and filter 2 deactivated, to avoid excessive processing time.
Dependency: The speed setpoint filter is parameterized using p1415 ... p1420 and p1421 ... p1426.
Description: Activates the velocity setpoint filters 1 and 2.
Recommend.: If only one filter is required, filter 1 should be activated and filter 2 deactivated, to avoid excessive processing time.
r1408.0...12 CO/BO: Status word closed-loop current control / ZSW curr ctrl
VECTOR (n/M) Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: - Func. diagram: 2530
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Current ctrl act Active Not active -
01 Id control, I-component limiting Active Not active -
03 Voltage limiting Active Not active -
10 Speed adaptation, limiting Active Not active -
11 Speed adaptation, speed deviation Out tolerance In tolerance 6719
12 Motor stalled Yes No 6719,
8018
p1412[0...n] Speed setpoint filter, dead time / n_set dead time
TM41 Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 9674
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.000 [ms] 1.000 [ms] 0.000 [ms]
p1414[0...n] Speed setpoint filter activation / n_set_filt active
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: DDS, p0180 Func. diagram: 5020
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Activate filter 1 Yes No -
01 Activate filter 2 Yes No -
p1414[0...n] Velocity setpoint filter activation / v_set_filt active
SERVO (Lin) Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: DDS, p0180 Func. diagram: 5020
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 0000 bin