Description: Sets the integral time of the speed controller after the adaptation speed range (> p1465). The entry is made referred
to the integral time for the lower adaptation speed range of the speed controller (% referred to p1462).
Dependency: Refer to: p1462, p1464, p1465
Note: If the upper transition point p1465 of the speed controller adaptation is set to lower values than the lower transition
point p1464, then the controller integral time below p1465 is adapted with p1463. This means that an adaptation
can be implemented for low speeds without having to change the controller parameters.
Description: Sets the lower adaptation speed of the speed controller. No adaptation is effective below this speed.
Dependency: Refer to: p1460, p1461, p1462, p1463, p1465
Description: Sets the lower adaptation velocity of the velocity controller. No adaptation is effective below this velocity.
Dependency: Refer to: p1460, p1461, p1462, p1463, p1465
Description: Sets the lower adaptation speed of the speed controller. No adaptation is effective below this speed.
Dependency: Refer to: p1460, p1461, p1462, p1463, p1465
Note: If the upper transition point p1465 of the speed controller adaptation is set to values less than the lower transition
point p1464, then the controller below p1465 is adapted with p1461 or p1463. This means that an adaptation can
be implemented for low speeds without having to change the controller parameters.
p1463[0...n] Speed controller Tn adaptation speed, upper scaling / n_ctrl Tn n upper
VECTOR (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 6050
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.0 [%] 200000.0 [%] 100.0 [%]
p1464[0...n] Speed controller adaptation speed, lower / n_ctrl n lower
SERVO Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5050
P-Group: Closed-loop control Units group: 3_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [RPM] 210000.00 [RPM] 0.00 [RPM]
p1464[0...n] Velocity controller adaptation velocity, lower / v_ctrl n lower
SERVO (Lin) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5050
P-Group: Closed-loop control Units group: 4_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [m/min] 1000.00 [m/min] 0.00 [m/min]
p1464[0...n] Speed controller adaptation speed, lower / n_ctrl n lower
VECTOR (n/M) Can be changed: U, T Calculated: CALC_MOD_CON Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 6050
P-Group: Closed-loop control Units group: 3_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [RPM] 210000.00 [RPM] 0.00 [RPM]