List of parameters
Parameters
1-425
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: For servo drives, the parameter is only effective in sensorless operation.
For vector drives, the acceleration pre-control is inhibited if the smoothing is set to the maximum value.
Description: Sets the smoothing time constant of the accelerating force.
Note: For servo drives, the parameter is only effective in sensorless operation.
Description: Displays the accelerating torque to pre-control the speed controller for torque-speed pre-control (p1402.4 = 1 or in
sensorless operation).
Index: [0] = Unsmoothed
[1] = Smoothed
Dependency: Refer to: p0341, p0342, p1300, p1402, r1493, p1497, p1498
Description: Displays the accelerating torque to pre-control the velocity controller for force- velocity pre-control (p1402.4 = 1 or in
sensorless operation).
Index: [0] = Unsmoothed
[1] = Smoothed
Dependency: Refer to: p0341, p0342, p1300, p1402, r1493, p1497, p1498
Description: Displays the accelerating torque for pre-control of the speed controller.
Index: [0] = Unsmoothed
[1] = Smoothed
Dependency: Refer to: p0341, p0342, p1496
p1517[0...n] Acceleration force smoothing time constant / F_accel T_smooth
SERVO (Lin) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5042, 5210
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [ms] 100.00 [ms] 4.00 [ms]
r1518[0...1] CO: Accelerating torque / M_accel
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5042, 5210
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
r1518[0...1] CO: Accelerating force / F_accel
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5042, 5210
P-Group: Closed-loop control Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [N] - [N] - [N]
r1518[0...1] CO: Accelerating torque / M_accel
VECTOR (n/M) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 6060
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]