EasyManua.ls Logo

Siemens SINAMICS S Series - p1517[0...n] Acceleration force smoothing time constant; F_accel T_smooth; r1518[0...1] CO: Accelerating torque; M_accel; r1518[0...1] CO: Accelerating force; F_accel

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of parameters
Parameters
1-425
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Note: For servo drives, the parameter is only effective in sensorless operation.
For vector drives, the acceleration pre-control is inhibited if the smoothing is set to the maximum value.
Description: Sets the smoothing time constant of the accelerating force.
Note: For servo drives, the parameter is only effective in sensorless operation.
Description: Displays the accelerating torque to pre-control the speed controller for torque-speed pre-control (p1402.4 = 1 or in
sensorless operation).
Index: [0] = Unsmoothed
[1] = Smoothed
Dependency: Refer to: p0341, p0342, p1300, p1402, r1493, p1497, p1498
Description: Displays the accelerating torque to pre-control the velocity controller for force- velocity pre-control (p1402.4 = 1 or in
sensorless operation).
Index: [0] = Unsmoothed
[1] = Smoothed
Dependency: Refer to: p0341, p0342, p1300, p1402, r1493, p1497, p1498
Description: Displays the accelerating torque for pre-control of the speed controller.
Index: [0] = Unsmoothed
[1] = Smoothed
Dependency: Refer to: p0341, p0342, p1496
p1517[0...n] Acceleration force smoothing time constant / F_accel T_smooth
SERVO (Lin) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5042, 5210
P-Group: Closed-loop control Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
0.00 [ms] 100.00 [ms] 4.00 [ms]
r1518[0...1] CO: Accelerating torque / M_accel
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5042, 5210
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
r1518[0...1] CO: Accelerating force / F_accel
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5042, 5210
P-Group: Closed-loop control Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [N] - [N] - [N]
r1518[0...1] CO: Accelerating torque / M_accel
VECTOR (n/M) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 6060
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]