Parameters
List of parameters
1-432
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Note: This parameter can be freely interconnected.
The value has the above significance if it is interconnected from connector input p1528.
Description: Displays the upper torque limit of all torque limits without offset.
Dependency: p1400 bit 4 = 0: Upper / lower
p1400 bit 4 = 1: Motoring / generating
Refer to: p1520, p1521, p1522, p1523, p1528, p1529
Description: Displays the upper force limit of all force limits without offset.
Dependency: p1400 bit 4 = 0: Upper / lower
p1400 bit 4 = 1: Motoring / generating
Refer to: p1520, p1521, p1522, p1523, p1528, p1529
Description: Displays the upper torque limit of all torque limits without offset.
Dependency: Refer to: p1520, p1521, p1522, p1523, p1528, p1529
Description: Displays the lower torque limit of all torque limits without offset.
r1526 Torque limit upper/motoring without offset / M_max up. w/o offs
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5620, 5630,
6630, 6640
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
r1526 Force limit upper/motoring without offset / F_max up. w/o offs
SERVO (Lin) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5620, 5630,
6630, 6640
P-Group: Closed-loop control Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [N] - [N] - [N]
r1526 Torque limit upper without offset / M_max up. w/o offs
VECTOR (n/M) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5620, 5630,
6630, 6640
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
r1527 Torque limit lower/regenerative without offset / M_max low w/o offs
SERVO Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5620, 5630,
6630, 6640
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]