Parameters
List of parameters
1-436
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the regenerative power limit.
Dependency: Refer to: p0500, p1530
Note: For VECTOR the following applies (p0107):
The power limit is limited to 300% rated motor power.
Description: Sets the torque offset for the torque limit.
Dependency: Refer to: p1520, p1521, p1522, p1523, p1528, p1529
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description: Sets the force offset for the force limit.
Dependency: Refer to: p1520, p1521, p1522, p1523, p1528, p1529
Notice: A BICO interconnection to a parameter that belongs to a drive objects always acts on the effective data set.
Description: Displays the maximum torque/force generating current as a result if all current limits.
p1531[0...n] Power limit regenerating / P_max gen
SERVO, VECTOR
(n/M)
Can be changed: U, T Calculated:
CALC_MOD_LIM_REF
Access level: 2
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5640, 6640
P-Group: Closed-loop control Units group: 14_5 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-100000.00 [kW] -0.01 [kW] -0.01 [kW]
p1532[0...n] CO: Torque limit offset / M_max offset
SERVO Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5620, 5630,
8012
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-100000.00 [Nm] 100000.00 [Nm] 0.00 [Nm]
p1532[0...n] CO: Force offset, force limit / F_max offset
SERVO (Lin) Can be changed: U, T Calculated: - Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 5620, 5630,
8012
P-Group: Closed-loop control Units group: 8_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
-100000.00 [N] 100000.00 [N] 0.00 [N]
r1533 Current limit torque-generating total / Iq_max total
SERVO, VECTOR
(n/M)
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: 5640, 5722,
6640
P-Group: Displays, signals Units group: 6_2 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
- [Arms] - [Arms] - [Arms]