Siemens SINAMICS S Series - p1545[0...n] BI: Activates travel to a fixed stop; TfS activation; p1546 Speed threshold motoring;regenerating; n_thresh mot;regen; p1546 Velocity threshold motoring;regenerating; v_thresh mot;regen; r1547[0...1] CO: Torque limit for speed controller output; M_max outp n_ctrl

Siemens SINAMICS S Series
1816 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of parameters
1-442
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source to activate/de-activate the "travel to fixed stop" function
1: Travel to fixed stop is active
0: Travel to fixed stop is inactive
Notice: The parameter may be protected as a result of p0922 or p2079 and cannot be changed.
Note: When traveling to fixed stop, the fault F07900 "motor blocked" is suppressed.
When the function module "position positioner" (r0108.4 = 1) is activated, this binector input is interconnected as
follows as standard:
BI: p1545 = r2683.14
Description: Sets the speed threshold for the motoring/regenerating limit.
For speeds where the absolute value is less than p1546, then the following applies:
- For p1400.13 = 0: Motoring limit (speed threshold is compared to the speed actual value).
- For p1400.13 = 1: Regenerative limiting (speed threshold is compared to the speed setpoint).
Description: Sets the velocity threshold for the motoring/regenerating limit.
For velocities where the absolute value is less than p1546, then the following applies:
- For p1400.13 = 0: Motoring limit (velocity threshold is compared to the velocity actual value).
- For p1400.13 = 1: Regenerative limiting (velocity threshold is compared to the velocity setpoint).
Description: Displays the torque limit to limit the speed controller output.
Index: [0] = Upper limit
[1] = Lower limit
p1545[0...n] BI: Activates travel to a fixed stop / TfS activation
VECTOR (n/M) Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: CDS, p0170 Func. diagram: 2520, 3617
P-Group: Commands Units group: - Unit selection: -
Not for motor type: REL Expert list: 1
Min Max Factory setting
- - 0
p1546 Speed threshold motoring/regenerating / n_thresh mot/regen
SERVO Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.0 [RPM] 210000.0 [RPM] 20.0 [RPM]
p1546 Velocity threshold motoring/regenerating / v_thresh mot/regen
SERVO (Lin) Can be changed: U, T Calculated: - Access level: 2
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: 4_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.0 [m/min] 1000.0 [m/min] 0.2 [m/min]
r1547[0...1] CO: Torque limit for speed controller output / M_max outp n_ctrl
VECTOR (n/M) Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: Closed-loop control Units group: 7_1 Unit selection: p0505
Not for motor type: REL Expert list: 1
Min Max Factory setting
- [Nm] - [Nm] - [Nm]