List of parameters
Parameters
1-587
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: r2197
Refer to: A07903
Note: Re bit 00:
Alarm A07903 is output when the bit is set with p2197.7 = 0 (n_set <> n_act).
Re bit 01:
When the bit is set, the load monitoring is only carried out in the 1st quadrant as a result of the positive characteris-
tic parameters (p2182 ... p2190).
Re bit 15:
The bit indicates as to whether the automatic parameterization (p0340 = 1, p3900 > 0) for the parameters of the
extended monitoring functions was carried out. If the bit is not set, e.g. when activating the configuration (refer to
p0108.15), the parameterization is automatically carried out when booting even if r3925.0 is already 1.
Description: Configuration word for signals and monitoring functions.
Dependency: Refer to: r2197
Refer to: A07903
Note: Re bit 00:
Alarm A07903 is output when the bit is set with p2197.7 = 0 (n_set <> n_act).
Re bit 01:
When the bit is set, the load monitoring is only carried out in the 1st quadrant as a result of the positive characteris-
tic parameters (p2182 ... p2190).
Re bit 15:
The bit indicates as to whether the automatic parameterization (p0340 = 1, p3900 > 0) for the parameters of the
extended monitoring functions was carried out. If the bit is not set, e.g. when activating the configuration (refer to
p0108.15), the parameterization is automatically carried out when booting even if r3925.0 is already 1.
Description: Sets the hysteresis speed (bandwidth) for the following signals:
"|n_act| < speed threshold value 3" (BO: r2199.0)
"n_set >= 0" (BO: r2198.5)
"n_act >= 0" (BO: r2197.3)
Bit field: Bit Signal name 1 signal 0 signal FP
00 Enable alarm A07903 Yes No 8010
01 Load monitoring only in the 1st quadrants Yes No 8010
15 Automatic parameterization carried out
(p0340 = 1, p3900 > 0)
Yes No -
p2149[0...n] Monitoring configuration / Monit config
VECTOR Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned16 Dynamic index: DDS, p0180 Func. diagram: 8010
P-Group: Messages Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0001 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Enable alarm A07903 Yes No 8010
01 Load monitoring only in the 1st quadrants Yes No 8010
15 Automatic parameterization carried out
(p0340 = 1, p3900 > 0)
Yes No -
p2150[0...n] Hysteresis speed 3 / n_hysteresis 3
SERVO, VECTOR Can be changed: U, T Calculated:
CALC_MOD_LIM_REF
Access level: 3
Data type: Floating Point Dynamic index: DDS, p0180 Func. diagram: 8010
P-Group: Messages Units group: 3_1 Unit selection: p0505
Not for motor type: - Expert list: 1
Min Max Factory setting
0.00 [RPM] 300.00 [RPM] 2.00 [RPM]