List of parameters
Parameters
1-669
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Description: Sets the signal source to enable the basic positioner.
BI: p2656 = 1 signal
The basic positioner is enabled.
BI: p2656 = 0 signal
The basic positioner is not enabled.
Dependency: Refer to: r2526, p2655
Description: Sets the signal source for the position actual value/position setting value.
Dependency: Refer to: r2521, p2658
Note: In the tracking mode, the position setpoint is taken from this connector input.
Description: Sets the signal source for the feedback signal "position actual value is valid".
BI: p2658 = 1 signal
The position actual value received via CI: p2657 is valid.
BI: p2658 = 0 signal
The position actual value received via CI: p2657 is invalid.
Dependency: Refer to: r2526, p2657
Note: While a 0 signal is present, the position setpoint (p2665) is held at the value of 0.
p2656 BI: EPOS enable basic positioner / EPOS enable
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3635
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 2526.3
p2657 CI: EPOS position actual value/position setting value / Pos act/set value
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Integer32 Dynamic index: - Func. diagram: 3635
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 2521[0]
p2658 BI: EPOS pos. actual value valid, feedback signal / Pos valid feedback
SERVO (EPOS),
VECTOR (EPOS)
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / Binary Dynamic index: - Func. diagram: 3635
P-Group: Basic positioner Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 2526.0