Parameters
List of parameters
1-682
© Siemens AG 2007 All Rights Reserved
SINAMICS S List Manual (LH1), 07/2007
Dependency: Refer to: p2005
Note: This parameter represents the numerical value of the reference quantity in the currently selected units and is only
available for interconnection with Drive Control Chart (DCC).
Description: Displays the actual reference quantity for temperatures.
All temperatures specified as relative value are referred to this reference quantity. The reference quantity in this
parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
Note: This parameter represents the numerical value of the reference quantity in the currently selected units and is only
available for interconnection with Drive Control Chart (DCC).
Description: Displays the actual reference quantity for acceleration rates.
All acceleration rates specified as relative value are referred to this reference quantity. The reference quantity in
this parameter corresponds to 100% or 4000 hex or 4000 0000 hex.
Dependency: r0108.12, p0505
Refer to: p2007
Note: This parameter represents the numerical value of the reference quantity in the currently selected units and is only
available for interconnection with Drive Control Chart (DCC).
Description: Sets the configuration for position tracking of a load gearbox.
Note: For the following events, the non-volatile, saved position values are automatically reset:
- when an encoder replacement has been identified.
- when changing the configuration of the Encoder Data Set (EDS).
r2706 CO: Reference temperature actual / Ref temp act
A_INF, B_INF,
SERVO, S_INF,
TM41, VECTOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
r2707 CO: Reference acceleration actual / Ref accel act
SERVO, SERVO
(Lin), TM41, VEC-
TOR
Can be changed: - Calculated: - Access level: 3
Data type: Floating Point Dynamic index: - Func. diagram: -
P-Group: - Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - -
p2720[0...n] Load gearbox configuration / Load grbx config
SERVO, VECTOR Can be changed: C2(1, 4) Calculated: - Access level: 1
Data type: Unsigned32 Dynamic index: DDS, p0180 Func. diagram: -
P-Group: Encoder Units group: - Unit selection: -
Not for motor type: - Expert list: 1
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Load gearbox, activate position tracking Yes No -
01 Axis type Linear axis Rotary axis -
02 Load gearbox, reset position Yes No -